[ Pobierz całość w formacie PDF ]

ÿþECHNICAL INFORMATION
PRODUCT
T
P 1 / 3
UB1100, UB1101
Models No.
Description
Blower
W
CONCEPTION AND MAIN APPLICATIONS
L
The above models are economical versions of our existing
Models 4014N and 4014NV, and feature the ergonomic
designed, new handle for more comfortable and controlled
operation.
H
UB1101 features variable speed control switch
while UB1100 is a single speed blower.
Dimensions : mm ( " )
Length ( L )
480 (18-7/8)
Width ( W ) 170 (6-11/16)
Height ( H ) 180 (7-1/8)
Specification
Continuous Rating (W)
Voltage (V) Current (A) Cycle (Hz) Max. Output(W)
Input Output
110 5.5 50 / 60 380
600 350
5.5
120 50 / 60 600 350 380
50 / 60 600 350 380
220 2.9
2.7
230 50 / 60 600 350 380
240 2.6
50 / 60 600 350 380
Model No.
UB1101 UB1100
600
Power input ( W )
No load speed : (min -1= rpm)
0 -16,000 16,000
Yes No
Variable switch
Lock on switch Yes
Air volume :m3/min. 0-2.8 2.8
Degree of vacuum : kPa (mmH2O) 0 - 5.5 (0 - 560) 5.5 (560)
Air speed : m/s 0 - 51 51
Cord length 5 (16.4)
Net weight :Kg (lbs )
1.7 (3.7)
Standard equipment
The product for export comes without any accessories.
The standard equipment for the tool shown may differ from country to country.
Optional accessories
* Dust bag * Flexible hose set
* Long nozzle * Anchor nozzle set
P 2 / 3
Repair
Assemble fan with meeting the screw hole of the armature shaft with the same of the fan.
And assemble the fan to the armature shaft by screwing pan head screw M4 x 12 as illustrated below.
Fastening torque for
pan head screw M4x12 : 0.69 - 0.98N.m
Pan head screw M4 x 12 (7.0 - 10 kgf.cm)
Screw hole
Fan
Pan head screw M4 x 12
Armature shaft
Screw hole
Circuit diagram
Color index of lead wires
Black
White
Power supply cord
Switch
M2
Field
1 2
Shrink these tubes
C1
with heat.
C2
M1
Noise suppressor
Wiring diagram
Field lead wires have to be fixed with lead holders as illustrated in Fig. A.
Lead holder
Shrink these tubes
with heat.
Lead holder
Fig. A
P 3 / 3
Wiring diagram
Pass the upper field wire
Ribs
between ribs and inner wall.
Pin
Boss
Do not slack the field lead wires
Pass the field lead wires
in the motor housing.
between pin and boss. [ Pobierz całość w formacie PDF ]